Bug 723208 - rhevh cannot be operating in serial console
Summary: rhevh cannot be operating in serial console
Keywords:
Status: CLOSED NOTABUG
Alias: None
Product: Red Hat Enterprise Linux 6
Classification: Red Hat
Component: ovirt-node
Version: 6.2
Hardware: All
OS: Linux
high
high
Target Milestone: rc
: ---
Assignee: Mike Burns
QA Contact: Virtualization Bugs
URL:
Whiteboard:
Depends On:
Blocks:
TreeView+ depends on / blocked
 
Reported: 2011-07-19 12:24 UTC by Guohua Ouyang
Modified: 2011-07-20 07:38 UTC (History)
5 users (show)

Fixed In Version:
Doc Type: Bug Fix
Doc Text:
Clone Of:
Environment:
Last Closed: 2011-07-20 07:38:24 UTC
Target Upstream Version:


Attachments (Terms of Use)

Description Guohua Ouyang 2011-07-19 12:24:14 UTC
Description of problem:
RHEV-H cannot be operating via serial console during install or after install.


Version-Release number of selected component (if applicable):
rhev-hypervisor-6.2-05

How reproducible:
Always.

Steps to Reproduce:
1. Launch RHEV-H install via pxe.
2. Append "console=ttyS0,115200n8" to boot params.
3. Open serial console by minicom or putty.
4. Tab to "Install Hypervisor 6.1" and hit enter.

Actual results:
No response, the installation cannot be continue in serial console.

Expected results:
RHEV-H can be operating in serial console.

Additional info:
Install rhev-h on tty0, then boot with console=ttyS0,115200n8, on serial console, cannot login, it doesn't accept any input.

Mark this regression as it's fixed in 6.1 in bug 676969 before.

Comment 3 Guohua Ouyang 2011-07-20 07:38:24 UTC
Sorry, it's minicom configure error, minicom cannot accept input due to "hardware flow control" is setting to "yes".  after change it to "no", then serial console works well.


Note You need to log in before you can comment on or make changes to this bug.