Hide Forgot
This bug has been copied from bug #732948 and has been proposed to be backported to 5.7 z-stream (EUS).
Created attachment 519645 [details] Patch
Test version: rhev-hypervisor-5.7-20110824.0.el5_7 Auto install to cciss can succeed. So change bug status to VERIFIED.
Technical note added. If any revisions are required, please edit the "Technical Notes" field accordingly. All revisions will be proofread by the Engineering Content Services team. New Contents: RAID arrays controlled by CCISS devices were not found by multipath configuration, so installation failed because it could not create physical volumes. The code has been updated so that RAID arrays controlled by CCISS devices are found by multipath configuration and installation on RAID arrays controlled by CCISS devices is now successful.
An advisory has been issued which should help the problem described in this bug report. This report is therefore being closed with a resolution of ERRATA. For more information on therefore solution and/or where to find the updated files, please follow the link below. You may reopen this bug report if the solution does not work for you. http://rhn.redhat.com/errata/RHBA-2011-1254.html