Hide Forgot
Description of problem: when configuring an Host with wrong PM settings, or when there is no Host Proxy, a message is shown in BE log, that should be reflected in webadmin. Version-Release number of selected component (if applicable): How reproducible: Always Steps to Reproduce: 1.Configure an Host with wrong params and press the OK button / Or configure PM when there is only one Host in the Cluster. 2. 3. Actual results: No Error message. Expected results: The BE error message should be reflected via an error message. Additional info: No proxy: fected : ID: cf51fd24-50a7-11e1-a45a-001a4a169746 Type: VDS 2012-02-06 12:47:57,357 ERROR [org.ovirt.engine.core.bll.FencingExecutor] (http--0.0.0.0-8080-8) Failed to run Power Management command on Host navy-vds1.qa.lab.tlv.redhat.com, no running proxy Host was found. only one Host:
The action of saving the Host PM configuration has succeeded, this is why there is no error that is being reflected in the web-admin. The PM itself might be configured wrongly; in order to find out whether the PM is configured wrongly or not, you have the "Test" button in the New/Edit Host dialog. If you haven't Tested explicitly the PM configuration and saved the Host as is, saving will succeed; the backend might perform the testing for you behind the scenes in this case; if this test fails, you will see an Event/Alert at the bottom of the application.