Bug 796961 - deployable/application page not detecting if hwp is missing
Summary: deployable/application page not detecting if hwp is missing
Keywords:
Status: CLOSED CURRENTRELEASE
Alias: None
Product: CloudForms Cloud Engine
Classification: Retired
Component: aeolus-conductor
Version: 1.0.0
Hardware: Unspecified
OS: Unspecified
unspecified
medium
Target Milestone: beta5
Assignee: Jozef Zigmund
QA Contact: pushpesh sharma
URL: https://qeblade31.rhq.lab.eng.bos.red...
Whiteboard:
Depends On:
Blocks:
TreeView+ depends on / blocked
 
Reported: 2012-02-23 22:53 UTC by wes hayutin
Modified: 2014-08-04 22:30 UTC (History)
6 users (show)

Fixed In Version:
Doc Type: Bug Fix
Doc Text:
Clone Of:
Environment:
Last Closed: 2012-08-30 17:16:34 UTC


Attachments (Terms of Use)
verified_screenshot (145.02 KB, image/png)
2012-04-17 10:23 UTC, pushpesh sharma
no flags Details

Description wes hayutin 2012-02-23 22:53:50 UTC
Description of problem:

1. setup aeolus
2. create a application blueprint w/ hwp called myHWP
3. conductor/catalogs/$x/deployables/$x
will show the component out line as valid.. good..

4. go delete myHWP
5. nav back to conductor/catalogs/$x/deployables/$x

The component outline still shows its valid, but its not.

Try to launch and you'll get an error the hwp is missing


[root@qeblade31 ~]# rpm -qa | grep aeolus
aeolus-conductor-daemons-0.8.0-35.el6.noarch
rubygem-aeolus-image-0.3.0-9.el6.noarch
rubygem-aeolus-cli-0.3.0-10.el6.noarch
aeolus-all-0.8.0-35.el6.noarch
aeolus-conductor-0.8.0-35.el6.noarch
aeolus-conductor-doc-0.8.0-35.el6.noarch
aeolus-configure-2.5.0-15.el6.noarch

Comment 1 Angus Thomas 2012-03-02 14:18:38 UTC
We need a check , on loading conductor/catalogs/$x/deployables/$x, that the HWP actaully reseolves correctly.

Comment 2 Jozef Zigmund 2012-03-07 19:08:01 UTC
I tried to reproduce it on commit # d6339725c86212329e85d1639644e9812ae96037 and it works as we expect, please verify it.

Comment 3 wes hayutin 2012-04-13 18:22:22 UTC
need QE to retest this

Comment 4 pushpesh sharma 2012-04-17 10:22:33 UTC
Marking this as verified as after deleting HWP application blue print clearly ask for repair. PFA for snap shot.  


[root@dhcp201-169 ~]# rpm -qa|grep aeolus
aeolus-configure-2.5.2-1.el6.noarch
aeolus-conductor-0.8.7-1.el6.noarch
rubygem-aeolus-cli-0.3.1-1.el6.noarch
aeolus-conductor-doc-0.8.7-1.el6.noarch
aeolus-all-0.8.7-1.el6.noarch
aeolus-conductor-daemons-0.8.7-1.el6.noarch
rubygem-aeolus-image-0.3.0-12.el6.noarch

Comment 5 pushpesh sharma 2012-04-17 10:23:02 UTC
Created attachment 577979 [details]
verified_screenshot


Note You need to log in before you can comment on or make changes to this bug.