Bug 2334810 (CVE-2024-56724) - CVE-2024-56724 kernel: mfd: intel_soc_pmic_bxtwc: Use IRQ domain for TMU device
Summary: CVE-2024-56724 kernel: mfd: intel_soc_pmic_bxtwc: Use IRQ domain for TMU device
Keywords:
Status: NEW
Alias: CVE-2024-56724
Product: Security Response
Classification: Other
Component: vulnerability
Version: unspecified
Hardware: All
OS: Linux
medium
medium
Target Milestone: ---
Assignee: Product Security DevOps Team
QA Contact:
URL:
Whiteboard:
Depends On:
Blocks:
TreeView+ depends on / blocked
 
Reported: 2024-12-29 12:01 UTC by OSIDB Bzimport
Modified: 2025-01-21 12:33 UTC (History)
4 users (show)

Fixed In Version:
Clone Of:
Environment:
Last Closed:
Embargoed:


Attachments (Terms of Use)

Description OSIDB Bzimport 2024-12-29 12:01:30 UTC
In the Linux kernel, the following vulnerability has been resolved:

mfd: intel_soc_pmic_bxtwc: Use IRQ domain for TMU device

While design wise the idea of converting the driver to use
the hierarchy of the IRQ chips is correct, the implementation
has (inherited) flaws. This was unveiled when platform_get_irq()
had started WARN() on IRQ 0 that is supposed to be a Linux
IRQ number (also known as vIRQ).

Rework the driver to respect IRQ domain when creating each MFD
device separately, as the domain is not the same for all of them.

Comment 1 Avinash Hanwate 2024-12-30 04:57:18 UTC
Upstream advisory:
https://lore.kernel.org/linux-cve-announce/2024122923-CVE-2024-56724-a800@gregkh/T


Note You need to log in before you can comment on or make changes to this bug.