Bug 2532232 (CVE-2026-89738) - CVE-2026-89738 kernel: Linux kernel: USB gadget `at91_udc` driver use-after-free vulnerability
Summary: CVE-2026-89738 kernel: Linux kernel: USB gadget `at91_udc` driver use-after-f...
Keywords:
Status: NEW
Alias: CVE-2026-89738
Product: Security Response
Classification: Other
Component: vulnerability
Version: unspecified
Hardware: All
OS: Linux
medium
medium
Target Milestone: ---
Assignee: Product Security DevOps Team
QA Contact:
URL:
Whiteboard:
Depends On:
Blocks:
TreeView+ depends on / blocked
 
Reported: 2026-09-11 21:33 UTC by OSIDB Bzimport
Modified: 2026-09-11 21:56 UTC (History)
15 users (show)

Fixed In Version:
Clone Of:
Environment:
Last Closed:
Embargoed:


Attachments (Terms of Use)

Description OSIDB Bzimport 2026-09-11 21:33:52 UTC
In the Linux kernel, the following vulnerability has been resolved:

usb: gadget: at91_udc: drain polled-VBUS timer/work before udc is freed

In polled-VBUS mode (board.vbus_pin && board.vbus_polled), probe arms a
self-restarting cycle: at91_vbus_timer() schedules vbus_timer_work, and
at91_vbus_timer_work() calls at91_vbus_update() and re-arms the timer via
mod_timer(). Both recover the same udc through container_of and dereference
it on every iteration.

Neither teardown path cancels this cycle. udc is devm-allocated, so it is
freed after at91udc_remove() returns, and is likewise freed when probe
fails and devres runs. A timer callback or work item that is pending or
running at either point dereferences the freed udc.

Add at91_udc_shutdown_vbus_timer() and call it from at91udc_remove() and
from the usb_add_gadget_udc() failure path in probe; the remaining probe
error paths fail before the timer is armed. timer_shutdown_sync() waits
for a running callback and clears timer->function, which makes the work
handler's mod_timer() a permanent no-op; cancel_work_sync() then drains
any pending or running work whose re-arm attempt now does nothing. The
timer must be shut down first, since cancelling the work alone would let
the timer re-queue it. The guard mirrors probe: in IRQ mode the timer and
work_struct are never initialized.

This does not require a fault; a normal driver unbind can interleave with
an already queued work item.

This issue was found by an in-house static analysis tool.