Summary: Brick Multiplexing: brick still down in heal info context(glfs) even though brick is online
Product: [Red Hat Storage] Red Hat Gluster Storage Reporter: Nag Pavan Chilakam <nchilaka>
Component: glusterdAssignee: Atin Mukherjee <amukherj>
Status: CLOSED ERRATA QA Contact: Nag Pavan Chilakam <nchilaka>
Severity: high Docs Contact:
Priority: unspecified    
Version: rhgs-3.3CC: nchilaka, rcyriac, rhs-bugs, storage-qa-internal, vbellur
Target Milestone: ---Keywords: ZStream
Target Release: RHGS 3.3.1 Async   
Hardware: Unspecified   
OS: Unspecified   
Whiteboard:
Fixed In Version: glusterfs-3.8.4-52.4 Doc Type: If docs needed, set a value
Doc Text:
Story Points: ---
Clone Of: Environment:
Last Closed: 2018-01-11 02:47:45 UTC Type: Bug
Regression: --- Mount Type: ---
Documentation: --- CRM:
Verified Versions: Category: ---
oVirt Team: --- RHEL 7.3 requirements from Atomic Host:
Cloudforms Team: --- Target Upstream Version:
Embargoed:

Description Nag Pavan Chilakam 2018-01-02 14:53:36 UTC
Description of problem:
======================
when verifying bz#1526373 - Brick Multiplexing: Gluster volume start force complains with command "Error : Request timed out" when there are multiple volumes 

heal info shows the brick as transport end point error, ie still not online.
even when the brick is online.
this obviously leads to more entries pending heals as more IOs are pumped in

the chance of hitting this problem is about 50%

Version-Release number of selected component (if applicable):
===========
glusterfs-server-3.8.4-52.3.el7rhgs.x86_64

How reproducible:
=================
2/4

Steps to Reproduce:

1. create a brick mux setup
2. create about 60 ecvols all 1x(4+2)
3. start the volumes
4. pump IOs to the base volume and another volume(i created an extra ecvol for this)
5.now kill a brick say b1
6. use volume force start of any volume(some vol in higher ascending order say vol15 or vol20 ...and not the base volume)
7. now start other volumes ie the mounted vols using vol force 




Actual results:
=========
healinfo still sees brick down
shd fails to start on one of the vols (raised a seperate BZ#1530217 - Brick multiplexing: glustershd fails to start on a volume force start after a brick is down)

logs of  BZ#1530217 can be used

Comment 10 errata-xmlrpc 2018-01-11 02:47:45 UTC
Since the problem described in this bug report should be
resolved in a recent advisory, it has been closed with a
resolution of ERRATA.

For information on the advisory, and where to find the updated
files, follow the link below.

If the solution does not work for you, open a new bug report.

https://access.redhat.com/errata/RHBA-2018:0083