Bug 1731873
Summary: | The page became blank when create instance on installed operator page | ||||||
---|---|---|---|---|---|---|---|
Product: | OpenShift Container Platform | Reporter: | Yanping Zhang <yanpzhan> | ||||
Component: | Management Console | Assignee: | Alec Merdler <amerdler> | ||||
Status: | CLOSED ERRATA | QA Contact: | Yadan Pei <yapei> | ||||
Severity: | medium | Docs Contact: | |||||
Priority: | high | ||||||
Version: | 4.2.0 | CC: | aos-bugs, jokerman, mmccomas, spadgett, yapei | ||||
Target Milestone: | --- | ||||||
Target Release: | 4.2.0 | ||||||
Hardware: | Unspecified | ||||||
OS: | Unspecified | ||||||
Whiteboard: | |||||||
Fixed In Version: | Doc Type: | If docs needed, set a value | |||||
Doc Text: | Story Points: | --- | |||||
Clone Of: | Environment: | ||||||
Last Closed: | 2019-10-16 06:30:16 UTC | Type: | Bug | ||||
Regression: | --- | Mount Type: | --- | ||||
Documentation: | --- | CRM: | |||||
Verified Versions: | Category: | --- | |||||
oVirt Team: | --- | RHEL 7.3 requirements from Atomic Host: | |||||
Cloudforms Team: | --- | Target Upstream Version: | |||||
Embargoed: | |||||||
Attachments: |
|
1.Cluster admin installs operator on cluster, eg, etcd. 2.On "Installed Operators" page, "etcd" operator is intalled successfully(It may take several minutes). 3.Click into "etcd". Click "Create Instance" for "etcd Cluster". Click "Edit Form". 4.In name field, edit the default name 'example' and change it to 'exampletest' 5.Set name with invalid values, hit Create will give error validation message Since the issue reported no longer exists, move to VERIFIED 4.2.0-0.nightly-2019-08-14-211610 Since the problem described in this bug report should be resolved in a recent advisory, it has been closed with a resolution of ERRATA. For information on the advisory, and where to find the updated files, follow the link below. If the solution does not work for you, open a new bug report. https://access.redhat.com/errata/RHBA-2019:2922 |
Created attachment 1592552 [details] blankpage Description of problem: When create instance from intalled operator page with "Edit Form" model, the page will become blank. Version-Release number of selected component (if applicable): 4.2.0-0.nightly-2019-07-21-222447 How reproducible: Always Steps to Reproduce: 1.Cluster admin installs operator on cluster, eg, etcd. 2.On "Installed Operators" page, "etcd" operator is intalled successfully(It may take several minutes). 3.Click into "etcd". Click "Create Instance" for "etcd Cluster". Click "Edit Form". 4.In name field, input "exampleetcd" Actual results: 4. The page became blank when input the name field. JS error: TypeError: e.currentTarget is nullconfigure-update-strategy-modal.tsx:11 Expected results: 4. Should not become blank when input name. Additional info: