Bug 1814554

Summary: Refrain from showing up the read-only fields in HC cockpit deployment wizard
Product: [oVirt] cockpit-ovirt Reporter: SATHEESARAN <sasundar>
Component: gluster-ansibleAssignee: Gobinda Das <godas>
Status: CLOSED CURRENTRELEASE QA Contact: SATHEESARAN <sasundar>
Severity: high Docs Contact:
Priority: unspecified    
Version: 0.14.2CC: bugs, godas, rhs-bugs
Target Milestone: ovirt-4.4.0Flags: sbonazzo: ovirt-4.4?
sbonazzo: planning_ack?
godas: devel_ack+
sasundar: testing_ack+
Target Release: ---   
Hardware: x86_64   
OS: Linux   
Whiteboard:
Fixed In Version: cockpit-ovirt-0.14.3-1.el8ev Doc Type: If docs needed, set a value
Doc Text:
Story Points: ---
Clone Of: 1814553 Environment:
Last Closed: 2020-05-20 20:01:13 UTC Type: ---
Regression: --- Mount Type: ---
Documentation: --- CRM:
Verified Versions: Category: ---
oVirt Team: Gluster RHEL 7.3 requirements from Atomic Host:
Cloudforms Team: --- Target Upstream Version:
Embargoed:
Bug Depends On:    
Bug Blocks: 1814553    

Description SATHEESARAN 2020-03-18 08:48:39 UTC
Description of problem:
------------------------
There are few fields which need not be shown in the cockpit deployment wizard UI, to make it less complex and helpful for customers to make quick judgement.

1. thinp checkbox in bricks tab
All bricks except 'engine' brick are thinp, engine brick is thick.
We do not allow users to modify it.

2.  Mount point of the brick
This is also the read-only value, generated based on the 'brick path' value' input from previous tab

3. Logical size of the brick
When VDO is used the size of the brick is 10 times the physical size of the brick.
Again this is a fixed value, read-only


Version-Release number of selected component (if applicable):
-------------------------------------------------------------
cockpit-ovirt-dashboard-0.14.2

How reproducible:
-----------------
Always

Expected results:
-----------------
Remove the read-only fields - thinp, mount point of the brick and logical size of the brick

Comment 1 SATHEESARAN 2020-03-30 14:42:05 UTC
The fix is available in cockpit-ovirt-dashboard-0.14.3

Comment 2 SATHEESARAN 2020-03-30 14:44:25 UTC
Tested with cockpit-ovirt-dashboard-0.14.3

The read-only fields in bricks tab - thinp checkbox, mount point of the brick and logical size of the brick - 
are hiddend and not exposed

Comment 3 Sandro Bonazzola 2020-05-20 20:01:13 UTC
This bugzilla is included in oVirt 4.4.0 release, published on May 20th 2020.

Since the problem described in this bug report should be
resolved in oVirt 4.4.0 release, it has been closed with a resolution of CURRENT RELEASE.