Bug 868240
Summary: | [WHQL][balloon]two warnings when running DevFund INF Test job for win8/win2012 | ||
---|---|---|---|
Product: | Red Hat Enterprise Linux 7 | Reporter: | Mike Cao <bcao> |
Component: | virtio-win | Assignee: | Gal Hammer <ghammer> |
Status: | CLOSED CURRENTRELEASE | QA Contact: | Virtualization Bugs <virt-bugs> |
Severity: | unspecified | Docs Contact: | |
Priority: | unspecified | ||
Version: | 7.0 | CC: | acathrow, bcao, bsarathy, ghammer, hhuang, juzhang, mdeng, michen, rhod, virt-maint |
Target Milestone: | rc | Keywords: | ZStream |
Target Release: | 7.0 | ||
Hardware: | Unspecified | ||
OS: | Unspecified | ||
Whiteboard: | |||
Fixed In Version: | virtio-win-prewhql-0.1-77 | Doc Type: | Bug Fix |
Doc Text: | Story Points: | --- | |
Clone Of: | Environment: | ||
Last Closed: | 2014-06-13 09:24:44 UTC | Type: | Bug |
Regression: | --- | Mount Type: | --- |
Documentation: | --- | CRM: | |
Verified Versions: | Category: | --- | |
oVirt Team: | --- | RHEL 7.3 requirements from Atomic Host: | |
Cloudforms Team: | --- | Target Upstream Version: | |
Embargoed: | |||
Bug Depends On: | |||
Bug Blocks: | 1091323 |
Description
Mike Cao
2012-10-19 10:28:05 UTC
Mike, Is this test run on the other drivers too? Because I see that the virtio-serial's inf file include the LoadOrderGroup directive and doesn't have PnpLockdown as well. Thanks. (In reply to comment #2) > Mike, > > Is this test run on the other drivers too? Because I see that the > virtio-serial's inf file include the LoadOrderGroup directive and doesn't > have PnpLockdown as well. > > Thanks. Yes . I Tried w/ serial on build 51 .hit the exactly same issue . But this bug is not urgent as HCk accepts warnings A patch which updated both serial and balloon's inf files was posted. Re-Test this issue on virtio-win-prewhql-75 Actual Results: Warnings on BALLOON display name is fixed ald . But it still shows following infos in the log file Running test on driver INF C:\Windows\Inf\oem1.inf Warning 3/20/2014 6:32:51.684 AM Driver package C:\Windows\Inf\oem1.inf does not use PnpLockdown directive in its version section. It is recommended to specify PnpLockdown = 1 in the version section. File: Line: -1 End Test 3/20/2014 6:32:51.684 AM DevFundInfTest::UsePnpLockdown Based on above ,this issue has not been fixed yet Reassign this issue Although the MSDN's documentation state that it is possible for the PnpLockdown value to be 0 to maintain backward compatibility, I've posted a set of patches which change the value to 1 for balloon, serial and rng. Vadim thinks that this change might affect the installer's behavior during an upgrade. Can you please verify it? Thanks. (In reply to Gal Hammer from comment #12) > Vadim thinks that this change might affect the installer's behavior during > an upgrade. Can you please verify it? Thanks. I tried driver upgrade from build71 to build79 ,did not find any issue QE Re-test the bug on build 79 on win2012/2012R2/win832/win864 OS Now,all warnings were gone from the logs and the job also could pass smoothly.so the issue has been fixed.Thanks. Best regards, Min Move status to VERiFied according to comment #14 Ronen , QE request thsi for rhel7.0.z Mike (In reply to Mike Cao from comment #17) > Ronen , QE request thsi for rhel7.0.z > > Mike Sorry My bad .PM clone it ald This request was resolved in Red Hat Enterprise Linux 7.0. Contact your manager or support representative in case you have further questions about the request. |