Bug 880684
| Summary: | ifup-aliases should check if master device is up before duplicity check and also allow to disable duplicate check for aliases | ||
|---|---|---|---|
| Product: | Red Hat Enterprise Linux 6 | Reporter: | Jan Ščotka <jscotka> |
| Component: | initscripts | Assignee: | Lukáš Nykrýn <lnykryn> |
| Status: | CLOSED ERRATA | QA Contact: | qe-baseos-daemons |
| Severity: | medium | Docs Contact: | |
| Priority: | high | ||
| Version: | 6.4 | CC: | azelinka, ovasik, tlavigne |
| Target Milestone: | rc | Keywords: | Regression |
| Target Release: | --- | ||
| Hardware: | Unspecified | ||
| OS: | Unspecified | ||
| Whiteboard: | |||
| Fixed In Version: | initscripts-9.03.36-1.el6 | Doc Type: | Bug Fix |
| Doc Text: |
Cause:
Arping, checking for ip duplicate on network, fails if parent device is not up.
Consequence:
Failure of arping was handled the same way as finding of second ip in network.
Fix:
Don't perform arping if parent device is down.
Result:
No error when parent device is down.
|
Story Points: | --- |
| Clone Of: | Environment: | ||
| Last Closed: | 2013-02-21 10:26:28 UTC | Type: | Bug |
| Regression: | --- | Mount Type: | --- |
| Documentation: | --- | CRM: | |
| Verified Versions: | Category: | --- | |
| oVirt Team: | --- | RHEL 7.3 requirements from Atomic Host: | |
| Cloudforms Team: | --- | Target Upstream Version: | |
| Embargoed: | |||
| Bug Depends On: | |||
| Bug Blocks: | 881827 | ||
|
Comment 6
errata-xmlrpc
2013-02-21 10:26:28 UTC
|