Bug 962658
Summary: | Out of order messages with grouping after failover | ||
---|---|---|---|
Product: | [JBoss] JBoss Enterprise Application Platform 6 | Reporter: | Andy Taylor <ataylor> |
Component: | HornetQ | Assignee: | Andy Taylor <ataylor> |
Status: | CLOSED CURRENTRELEASE | QA Contact: | |
Severity: | medium | Docs Contact: | |
Priority: | unspecified | ||
Version: | 6.1.0 | CC: | csuconic, mnovak, myarboro, rsvoboda |
Target Milestone: | ER7 | ||
Target Release: | EAP 6.1.1 | ||
Hardware: | Unspecified | ||
OS: | Unspecified | ||
Whiteboard: | |||
Fixed In Version: | Doc Type: | Bug Fix | |
Doc Text: | Story Points: | --- | |
Clone Of: | Environment: | ||
Last Closed: | 2013-09-16 20:22:58 UTC | Type: | Bug |
Regression: | --- | Mount Type: | --- |
Documentation: | --- | CRM: | |
Verified Versions: | Category: | --- | |
oVirt Team: | --- | RHEL 7.3 requirements from Atomic Host: | |
Cloudforms Team: | --- | Target Upstream Version: | |
Embargoed: |
Description
Andy Taylor
2013-05-14 07:47:08 UTC
Andy Taylor <ataylor> updated the status of jira HORNETQ-1194 to Resolved BZ is in incorrect state. Fix for this issue is present in EAP 6.1.1.ER7(HQ 2.3.5.Final) Verified using provided test in EAP 6.1.1.ER7. Great work, Andy! Removing jboss-eap-6.2.0 flag because it's fixed in EAP 6.1.1 |