Created attachment 813707 [details] screenshot Description of problem: I updated configuration of EAP6 datasource which was still enabled. This update failed (correctly) but the UI showed a successful message. Version-Release number of selected component (if applicable): Version: 4.10.0-SNAPSHOT Build Number: 9eb9b7d How reproducible: Always Steps to Reproduce: 1. navigate to EAP6 standalone resource->datasources->ExampleDS (if there is no datasource, create one) 2. go to configuration tab 3. change 'max pool size' property 4. click on save button Actual results: see attached screen shot - successful messages shows that current version is 10372, but on configuration history tab, you can see as current version 10281 and version 10372 has status failed Expected results: Error message should be shown
branch: master link: https://github.com/rhq-project/rhq/commit/10e13d811 time: 2014-04-30 12:50:41 +0200 commit: 10e13d8118304efb8b287d5eacf24909fd8934cf author: Jirka Kremser - jkremser message: [BZ 1020807] - UI shows successful message even though an update of configuration failed - Changing the message from "Configuration updated..." to "Updating configuration...", because we cannot predict if the configuration update will or will not be successful.
Verified on Version : 4.12.0-SNAPSHOT Build Number : 03bc193
Bulk closing of RHQ 4.11 issues, now that RHQ 4.12 is out. If you find an issue with those, please open a new BZ, linking to the old one.