Bug 1062159 - Dist-geo-rep : monitor got killed in intermediate master in cascaded setup while syncing meta data with "ValueError: signal only works in main thread"
Summary: Dist-geo-rep : monitor got killed in intermediate master in cascaded setup wh...
Keywords:
Status: CLOSED DUPLICATE of bug 1044420
Alias: None
Product: Red Hat Gluster Storage
Classification: Red Hat Storage
Component: geo-replication
Version: 2.1
Hardware: x86_64
OS: Linux
urgent
urgent
Target Milestone: ---
: ---
Assignee: Bug Updates Notification Mailing List
QA Contact: Sudhir D
URL:
Whiteboard:
Depends On:
Blocks:
TreeView+ depends on / blocked
 
Reported: 2014-02-06 11:05 UTC by Vijaykumar Koppad
Modified: 2014-08-25 00:50 UTC (History)
6 users (show)

Fixed In Version:
Doc Type: Bug Fix
Doc Text:
Clone Of:
Environment:
Last Closed: 2014-07-07 06:55:50 UTC
Embargoed:


Attachments (Terms of Use)

Description Vijaykumar Koppad 2014-02-06 11:05:25 UTC
Description of problem:  monitor got killed in intermediate master in cascaded setup while syncing meta data with "ValueError: signal only works in main thread". 

Backtrace in geo-rep intermediate master log-file

>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>
[2014-02-06 17:51:14.20453] I [master(/bricks/brick6):438:crawlwrap] _GMaster: crawl interval: 60 seconds
[2014-02-06 17:52:10.319305] E [syncdutils(monitor):240:log_raise_exception] <top>: FAIL: 
Traceback (most recent call last):
  File "/usr/libexec/glusterfs/python/syncdaemon/syncdutils.py", line 266, in twrap
    tf(*aa)
  File "/usr/libexec/glusterfs/python/syncdaemon/monitor.py", line 190, in wmon
    cpid, _ = self.monitor(w, argv, cpids)
  File "/usr/libexec/glusterfs/python/syncdaemon/monitor.py", line 161, in monitor
    self.terminate()
  File "/usr/libexec/glusterfs/python/syncdaemon/monitor.py", line 89, in terminate
    set_term_handler(lambda *a: set_term_handler())
  File "/usr/libexec/glusterfs/python/syncdaemon/syncdutils.py", line 332, in set_term_handler
    signal(SIGTERM, hook)
ValueError: signal only works in main thread
[2014-02-06 17:52:10.341447] I [syncdutils(monitor):192:finalize] <top>: exiting.
>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>

Version-Release number of selected component (if applicable):glusterfs-3.4.0.59rhs-1


How reproducible: This happens often.


Steps to Reproduce:
1.create a geo-rep relationship in a cascaded setup. ( master->imaster->slave)
2.create data on master
3.start geo-rep relation ship between master and imaster.
4.wait for it to sync to imaster,
5.after it syncs completely to imaster, start geo-rep between imaster and slave
6.Check if the monitor gets killed, if not try the above steps again. 

Actual results: monitor got killed in intermediate master with "ValueError: signal only works in main thread"


Expected results: Monitor should never be killed. 


Additional info:

Comment 2 Aravinda VK 2014-07-07 06:55:50 UTC

*** This bug has been marked as a duplicate of bug 1044420 ***