Comment 2 Steve Reichard 2014-09-19 19:48:17 UTC
BTW, simple to workaround

workaround is

issue a 'pcs status' on each controller
The node with has
'
Daemon Status: corosync: active/disabled
pacemaker: active/disabled
pcsd: active/enabled
'

you will need to issue
systemctl enable pacemaker
systemctl enable corosync

Comment 3 Ofer Blaut 2015-12-16 13:44:58 UTC
"
This bug was closed as part of a backlog clean up.