Description of problem: When a VDSM comes to up, the engine is not sending ConnectStorageServer for Fiber Channel storage domain. Version-Release number of selected component (if applicable): How reproducible: 100% Steps to Reproduce: 1. Create a FC SD 2. Move host to maintenance and back to up 3. No ConnectStorageServer command is send to host for fiber channel Actual results: No ConnectStorageServer command is send to host for fiber channel Expected results: ConnectStorageServer command is send to host for fiber channel Additional info: This behavior is needed to perform rescan of FC devices , to detect new ones and rescan sizes of existing ones.
Fred, how is this bug related to bug 1093007?
Not related. I just cloned from it .
ConnectStorageServer is called while having only FC storage domains in the DC during host activation: - Activation from maintenance - Activation after vdsm restart For storage domain domain activation / deactivation, connectStorageServer is not called while there are only FC domains in the DC. Fred, setting need-info on you just so you'll confirm this is the desired behaviour. moving to VERIFIED. Tested using: vdsm-4.17.10.1-0.el7ev.noarch rhevm-3.6.0.2-0.1.el6.noarch
It is the desired behaviour.
Since oVirt 3.6.0 has been released, moving from verified to closed current release.