Bug 1278590 - Controller node does not fully detach multipath device and the device can not be removed by manual means
Summary: Controller node does not fully detach multipath device and the device can not...
Keywords:
Status: CLOSED ERRATA
Alias: None
Product: Red Hat OpenStack
Classification: Red Hat
Component: openstack-cinder
Version: 5.0 (RHEL 7)
Hardware: Unspecified
OS: Unspecified
urgent
urgent
Target Milestone: async
: 5.0 (RHEL 7)
Assignee: Eric Harney
QA Contact: nlevinki
URL:
Whiteboard:
Depends On: 1255523 1280401 1280409
Blocks:
TreeView+ depends on / blocked
 
Reported: 2015-11-05 21:45 UTC by Scott Lewis
Modified: 2019-09-12 09:14 UTC (History)
10 users (show)

Fixed In Version: openstack-cinder-2014.1.5-2.el7ost
Doc Type: Bug Fix
Doc Text:
Clone Of: 1255523
Environment:
Last Closed: 2015-12-22 14:25:46 UTC
Target Upstream Version:
Embargoed:


Attachments (Terms of Use)


Links
System ID Private Priority Status Summary Last Updated
Red Hat Product Errata RHBA-2015:2689 0 normal SHIPPED_LIVE openstack-cinder bug fix advisory 2015-12-22 19:23:32 UTC

Comment 1 Sergey Gotliv 2015-11-10 06:12:30 UTC
Fixed in openstack-cinder-2014.1.5-2.el7ost

Comment 4 errata-xmlrpc 2015-12-22 14:25:46 UTC
Since the problem described in this bug report should be
resolved in a recent advisory, it has been closed with a
resolution of ERRATA.

For information on the advisory, and where to find the updated
files, follow the link below.

If the solution does not work for you, open a new bug report.

https://rhn.redhat.com/errata/RHBA-2015-2689.html