Description of problem: After a certain amount of time the EventCatcher thread is being stopped and deleted. from evm.log it is clear that the Event Monitor is gone and it attempts to restart every second ("Event Monitor Thread gone. Restarting..."). Version-Release number of selected component (if applicable): cfme-5.5.0 How reproducible: 100% Steps to Reproduce: 1. add a Openshift provider and refresh it 2. wait for the EventCatcher worker to start running and verify that it's status is started ($ bundle exec rake evm:status) and that it starts to collect events. 3. wait several hours (at least for me) and check that the worker is dead (easily detected in the evm.log and doesn't appear in the workers table ($ bundle exec rake evm:status) Actual results: events collection is stopped Expected results: events should be collected at all time and worker status should be started Additional info:
Proposed fix: https://github.com/ManageIQ/manageiq/pull/5626
*** Bug 1286618 has been marked as a duplicate of this bug. ***
*** This bug has been marked as a duplicate of bug 1281746 ***
This is not a duplicate of #1281746 it happens on 5.5.0.11 as well.
verified on cfme-5.5.0.13-1.el7cf.x86_64
Since the problem described in this bug report should be resolved in a recent advisory, it has been closed with a resolution of ERRATA. For information on the advisory, and where to find the updated files, follow the link below. If the solution does not work for you, open a new bug report. https://access.redhat.com/errata/RHSA-2015:2551