Created attachment 1199012 [details] Screenshot of the bug Description of problem: There is no "operation" dropdown in condition expression editor for registry based criteria. Version-Release number of selected component (if applicable): 5.6.1.2.20160810181333_8ba817b How reproducible: Always Steps to Reproduce: 1. Navigate to Control->Explorer. 2. Expand Conditions accordion. 3. Start to create a condition. 4. In the dropdown menu select "Registry". Actual results: Only three input fields appears, there is no dropdown with "STARTS WITH", "=", "INCLUDES" and so on. Expected results: "operation" dropdown should be presented.
This issue has been fixed in https://github.com/ManageIQ/manageiq/pull/10206 *** This bug has been marked as a duplicate of bug 1361577 ***