Bug 1555333
| Summary: | Can't press 'start' button when have low screen resolution | ||||||||
|---|---|---|---|---|---|---|---|---|---|
| Product: | [oVirt] cockpit-ovirt | Reporter: | Ido Rosenzwig <irosenzw> | ||||||
| Component: | Hosted Engine | Assignee: | Phillip Bailey <phbailey> | ||||||
| Status: | CLOSED CURRENTRELEASE | QA Contact: | Yihui Zhao <yzhao> | ||||||
| Severity: | high | Docs Contact: | |||||||
| Priority: | unspecified | ||||||||
| Version: | 0.11.7 | CC: | bugs, cshao, rbarry, stirabos | ||||||
| Target Milestone: | ovirt-4.2.2 | Flags: | rule-engine:
ovirt-4.2+
yzhao: testing_ack+ |
||||||
| Target Release: | 0.11.17 | ||||||||
| Hardware: | Unspecified | ||||||||
| OS: | Unspecified | ||||||||
| Whiteboard: | |||||||||
| Fixed In Version: | Doc Type: | If docs needed, set a value | |||||||
| Doc Text: | Story Points: | --- | |||||||
| Clone Of: | Environment: | ||||||||
| Last Closed: | 2018-03-29 11:17:04 UTC | Type: | Bug | ||||||
| Regression: | --- | Mount Type: | --- | ||||||
| Documentation: | --- | CRM: | |||||||
| Verified Versions: | Category: | --- | |||||||
| oVirt Team: | Integration | RHEL 7.3 requirements from Atomic Host: | |||||||
| Cloudforms Team: | --- | Target Upstream Version: | |||||||
| Embargoed: | |||||||||
| Attachments: |
|
||||||||
Created attachment 1408329 [details]
fix_1117.png
Can reproduce with this issue using cockpit-ovirt-dashboard-0.11.15-0.1.el7ev.noarch
And cockpit-ovirt-dashboard-0.11.17-1.el7ev.noarch should be fixed this issue.
See the attachment 1408329 [details].
From the Comment 2, it should be fixed with cockpit-ovirt-dashboard-0.11.17-1.el7ev.noarch, I will change the bug's status to verified when it becomes ON_QA. This bugzilla is included in oVirt 4.2.2 release, published on March 28th 2018. Since the problem described in this bug report should be resolved in oVirt 4.2.2 release, it has been closed with a resolution of CURRENT RELEASE. If the solution does not work for you, please open a new bug report. |
Created attachment 1407996 [details] Screen capture Description of problem: The user can't press the 'Start' button if the screen configured with low resolution. see screenshot attached. How reproducible: 100% Steps to Reproduce: 1. configure resolution of 1280 x 720 2. open web UI to deploy Hosted-engine 3. can't press the 'start' button