Bug 1637378 - [composable octavia] Octavia logs are missing on the networker node after installation
Summary: [composable octavia] Octavia logs are missing on the networker node after ins...
Keywords:
Status: CLOSED ERRATA
Alias: None
Product: Red Hat OpenStack
Classification: Red Hat
Component: openstack-tripleo-heat-templates
Version: 13.0 (Queens)
Hardware: Unspecified
OS: Unspecified
urgent
urgent
Target Milestone: z3
: 13.0 (Queens)
Assignee: Brent Eagles
QA Contact: Alexander Stafeyev
URL:
Whiteboard:
: 1637392 (view as bug list)
Depends On:
Blocks: 1624624 1637657
TreeView+ depends on / blocked
 
Reported: 2018-10-09 07:30 UTC by Aviv Guetta
Modified: 2020-01-21 16:12 UTC (History)
12 users (show)

Fixed In Version: openstack-tripleo-heat-templates-8.0.7-4.el7ost
Doc Type: If docs needed, set a value
Doc Text:
Clone Of:
: 1637657 (view as bug list)
Environment:
Last Closed: 2018-11-13 22:29:59 UTC
Target Upstream Version:
Embargoed:


Attachments (Terms of Use)


Links
System ID Private Priority Status Summary Last Updated
Launchpad 1796934 0 None None None 2018-10-09 16:57:54 UTC
OpenStack gerrit 609049 0 None MERGED Set octavia log directory permissions to octavia user 2021-02-03 10:47:38 UTC
OpenStack gerrit 611207 0 None MERGED Set octavia log directory permissions to octavia user 2021-02-03 10:47:38 UTC
Red Hat Product Errata RHBA-2018:3587 0 None None None 2018-11-13 22:30:59 UTC

Description Aviv Guetta 2018-10-09 07:30:43 UTC
Description of problem:
After "composable Octavia" (octavia-api on controllers, octavia-worker, octavia-healthmanager and octavia-housekeeping manager on are installed on the networker node) deployment, Octavia logs directory on the networker node is empty:
~~~
[root@networker-0 ~]# ll /var/log/containers/octavia/
total 0
~~~
Logs directory on the controller seem to be correct (only api.log).

Version-Release number of selected component (if applicable):
- RHOSP 13
- composable Octavia  - octavia-api on controllers, octavia-worker, octavia-healthmanager and octavia-housekeeping manager on are installed on the networker node.

Actual results:
Empty logs directory

Expected results:
octavia-worker, octavia-healthmanager and octavia-housekeeping manager log files listed in /var/log/containers/octavia/ on the networker node.

Additional info:
Note: Composable Octavia isn't officially supported in OSP 13.

Comment 2 Brent Eagles 2018-10-09 16:59:48 UTC
*** Bug 1637392 has been marked as a duplicate of this bug. ***

Comment 11 errata-xmlrpc 2018-11-13 22:29:59 UTC
Since the problem described in this bug report should be
resolved in a recent advisory, it has been closed with a
resolution of ERRATA.

For information on the advisory, and where to find the updated
files, follow the link below.

If the solution does not work for you, open a new bug report.

https://access.redhat.com/errata/RHBA-2018:3587