Bug 1777944 - BETA - RHCS4 Installation docs - warning about device naming with multiple controllers
Summary: BETA - RHCS4 Installation docs - warning about device naming with multiple co...
Keywords:
Status: CLOSED CURRENTRELEASE
Alias: None
Product: Red Hat Ceph Storage
Classification: Red Hat Storage
Component: Documentation
Version: 4.0
Hardware: Unspecified
OS: Unspecified
medium
high
Target Milestone: rc
: 4.0
Assignee: Ranjini M N
QA Contact: Tejas
URL:
Whiteboard:
Depends On:
Blocks: 1708370
TreeView+ depends on / blocked
 
Reported: 2019-11-28 18:39 UTC by Heðin
Modified: 2020-03-09 15:24 UTC (History)
6 users (show)

Fixed In Version:
Doc Type: If docs needed, set a value
Doc Text:
Clone Of:
Environment:
Last Closed: 2020-03-09 15:24:22 UTC
Embargoed:


Attachments (Terms of Use)

Description Heðin 2019-11-28 18:39:58 UTC
Description of problem:
Documentation does not inform about how to handle multiple disk controllers.
An example of such a setup is Dell R740xd with Dell BOSS module(ahci driver) for OS and H330(LSI3008) for OSD's.

Steps to Reproduce:
1. Install rhel
2. Reboot a few times, at some point ahci driver is loaded after the H330 driver
3. result is that boot device name has changed.

Expected results:
Troubleshooting section should state that this can be an issue and link to https://access.redhat.com/solutions/2720551

Comment 1 RHEL Program Management 2019-11-28 18:40:05 UTC
Please specify the severity of this bug. Severity is defined here:
https://bugzilla.redhat.com/page.cgi?id=fields.html#bug_severity.

Comment 4 Heðin 2020-01-19 23:06:07 UTC
Dell seems to push/recommend to use their BOSS module for hardware raid on m2.
This implies that this issue will not be a corner case but rather common.