Bug 1962483 - [RHEL7][RBD][4.6.z clone] FailedMount error when using restored PVC on app pod
Summary: [RHEL7][RBD][4.6.z clone] FailedMount error when using restored PVC on app pod
Keywords:
Status: CLOSED ERRATA
Alias: None
Product: Red Hat OpenShift Container Storage
Classification: Red Hat Storage
Component: csi-driver
Version: 4.6
Hardware: Unspecified
OS: Unspecified
unspecified
high
Target Milestone: ---
: OCS 4.6.5
Assignee: Rakshith
QA Contact: Jilju Joy
URL:
Whiteboard:
Depends On: 1956232 1962484
Blocks: 1964865
TreeView+ depends on / blocked
 
Reported: 2021-05-20 07:50 UTC by Mudit Agarwal
Modified: 2021-06-17 15:46 UTC (History)
11 users (show)

Fixed In Version: 4.6.5-411.ci
Doc Type: Bug Fix
Doc Text:
Currently, a newly restored PVC can not be mounted if some of the OpenShift Container Platform nodes are running on a version of Red Hat Enterprise Linux which is less than 8.2, and the snapshot from which the PVC was restored is deleted. Workaround: Do not delete the snapshot from which the PVC was restored until the restored PVC is deleted.
Clone Of: 1956232
Environment:
Last Closed: 2021-06-17 15:46:46 UTC
Embargoed:


Attachments (Terms of Use)


Links
System ID Private Priority Status Summary Last Updated
Red Hat Product Errata RHSA-2021:2479 0 None None None 2021-06-17 15:46:53 UTC

Comment 7 Jilju Joy 2021-05-27 09:53:03 UTC
Verified using the test case tests/manage/pv_services/pvc_snapshot/test_snapshot_at_different_pvc_utlilization_level.py::TestSnapshotAtDifferentPvcUsageLevel::test_snapshot_at_different_usage_level.
The test case deletes snapshot before attaching the restored RBD PVC to the pods.

Worker nodes kernel version is 3.10.0-1160.25.1.el7.x86_64

Verified in version:
OCS 4.6.5-411.ci
OCP 4.6.0-0.nightly-2021-05-27-000320
Ceph 14.2.11-147.el8cp (1f54d52f20d93c1b91f1ec6af4c67a4b81402800) nautilus (stable)
rook_csi_ceph	cephcsi@sha256:2fee74dd326bba49c6e1c029beeb973ba238e8bf17818d9561b2672dc69de004

Comment 8 Jilju Joy 2021-05-27 09:55:01 UTC
(In reply to Jilju Joy from comment #7)
> Verified using the test case
> tests/manage/pv_services/pvc_snapshot/
> test_snapshot_at_different_pvc_utlilization_level.py::
> TestSnapshotAtDifferentPvcUsageLevel::test_snapshot_at_different_usage_level.
Test case log - http://magna002.ceph.redhat.com/ocsci-jenkins/openshift-clusters/jijoy-may27/jijoy-may27_20210527T045858/logs/ocs-ci-logs-1622100402/tests/manage/pv_services/pvc_snapshot/test_snapshot_at_different_pvc_utlilization_level.py/
> The test case deletes snapshot before attaching the restored RBD PVC to the
> pods.
> 
> Worker nodes kernel version is 3.10.0-1160.25.1.el7.x86_64
> 
> Verified in version:
> OCS 4.6.5-411.ci
> OCP 4.6.0-0.nightly-2021-05-27-000320
> Ceph 14.2.11-147.el8cp (1f54d52f20d93c1b91f1ec6af4c67a4b81402800) nautilus
> (stable)
> rook_csi_ceph
> cephcsi@sha256:
> 2fee74dd326bba49c6e1c029beeb973ba238e8bf17818d9561b2672dc69de004

Comment 18 errata-xmlrpc 2021-06-17 15:46:46 UTC
Since the problem described in this bug report should be
resolved in a recent advisory, it has been closed with a
resolution of ERRATA.

For information on the advisory (Moderate: Red Hat OpenShift Container Storage 4.6.5 security and bug fix update), and where to find the updated
files, follow the link below.

If the solution does not work for you, open a new bug report.

https://access.redhat.com/errata/RHSA-2021:2479


Note You need to log in before you can comment on or make changes to this bug.