Bug 1983933 - [oVirt] CSI expansion should work in offline mode
Summary: [oVirt] CSI expansion should work in offline mode
Keywords:
Status: CLOSED ERRATA
Alias: None
Product: OpenShift Container Platform
Classification: Red Hat
Component: Storage
Version: 4.9
Hardware: Unspecified
OS: Unspecified
high
high
Target Milestone: ---
: 4.9.0
Assignee: Gal Zaidman
QA Contact: Gal Zaidman
URL:
Whiteboard:
Depends On: 1983930
Blocks: 1953674
TreeView+ depends on / blocked
 
Reported: 2021-07-20 08:28 UTC by Gal Zaidman
Modified: 2021-10-18 17:40 UTC (History)
3 users (show)

Fixed In Version:
Doc Type: If docs needed, set a value
Doc Text:
Clone Of:
Environment:
Last Closed: 2021-10-18 17:40:26 UTC
Target Upstream Version:
Embargoed:


Attachments (Terms of Use)


Links
System ID Private Priority Status Summary Last Updated
Github openshift ovirt-csi-driver pull 83 0 None None None 2021-08-01 07:23:19 UTC
Red Hat Product Errata RHSA-2021:3759 0 None None None 2021-10-18 17:40:43 UTC

Description Gal Zaidman 2021-07-20 08:28:47 UTC
Description of problem:

In Openshift 4.9 we added the csi-resizer.
Currently, the resizer doesn't work in OFFLINE mode due to an implementation based on DiskAttachments and the fact that the NodeStage Cap needs fixing[1].
Once BZ[1] is done we should port to implementation based on Disk objects to support OFFLINE expansion.

[1] https://bugzilla.redhat.com/show_bug.cgi?id=1983930
Version-Release number of selected component (if applicable):

How to test:
make sure test case:
"External Storage [Driver: csi.ovirt.org] [Testpattern: Dynamic PV (default fs)(allowExpansion)] volume-expand Verify if offline PVC expansion works"
passes

Comment 2 michal 2021-08-06 10:17:45 UTC
if I create pvc without pod and resize of pvc works, is it enough to check?

Comment 3 Gal Zaidman 2021-08-08 07:18:38 UTC
(In reply to michal from comment #2)
> if I create pvc without pod and resize of pvc works, is it enough to check?

yes, also in CSI tests I see this is working so we have a pretty good coverage

Comment 4 michal 2021-08-08 07:26:59 UTC
step to reproduce:
1) Create PVC and don't create any pod 
2) resize storage of PVC
3) Check that size of storage update
actual:
size updated successfully.

Comment 7 errata-xmlrpc 2021-10-18 17:40:26 UTC
Since the problem described in this bug report should be
resolved in a recent advisory, it has been closed with a
resolution of ERRATA.

For information on the advisory (Moderate: OpenShift Container Platform 4.9.0 bug fix and security update), and where to find the updated
files, follow the link below.

If the solution does not work for you, open a new bug report.

https://access.redhat.com/errata/RHSA-2021:3759