Bug 2018459 - Track VM with port connected to external network does not reach the ovnmetadata namespace
Summary: Track VM with port connected to external network does not reach the ovnmetada...
Keywords:
Status: CLOSED CURRENTRELEASE
Alias: None
Product: Red Hat OpenStack
Classification: Red Hat
Component: python-networking-ovn
Version: 16.2 (Train)
Hardware: Unspecified
OS: Unspecified
high
high
Target Milestone: z2
: 16.2 (Train on RHEL 8.4)
Assignee: Jakub Libosvar
QA Contact: Eran Kuris
URL:
Whiteboard:
: 2017424 2018980 (view as bug list)
Depends On:
Blocks: 2018365 2018980
TreeView+ depends on / blocked
 
Reported: 2021-10-29 11:35 UTC by Eduardo Olivares
Modified: 2022-02-09 12:07 UTC (History)
9 users (show)

Fixed In Version:
Doc Type: If docs needed, set a value
Doc Text:
Clone Of:
Environment:
Last Closed: 2022-02-09 12:07:02 UTC
Target Upstream Version:
Embargoed:


Attachments (Terms of Use)


Links
System ID Private Priority Status Summary Last Updated
Red Hat Issue Tracker OSP-10596 0 None None None 2021-11-10 14:26:41 UTC

Description Eduardo Olivares 2021-10-29 11:35:23 UTC
(previous description of this BZ was moved to BZ2019938 as per DFG decision)

This bug is now just used to track BZ2018365 in OSP. The explanation for the other issue is still available at BZ2019938.

Comment 1 Eran Kuris 2021-11-02 08:21:52 UTC
*** Bug 2018980 has been marked as a duplicate of this bug. ***

Comment 2 Karrar Fida 2021-11-02 19:21:38 UTC
@ekuris is this the corresponding OSP tracking bug for BZ2017424? If so we need a blocker request on this one.

Comment 3 Eran Kuris 2021-11-03 07:16:53 UTC
(In reply to Karrar Fida from comment #2)
> @ekuris is this the corresponding OSP tracking bug for BZ2017424?
> If so we need a blocker request on this one.

Yes it is

Comment 4 Numan Siddique 2021-11-03 15:23:58 UTC
By some cases I mean this - 

If a neutron router is connected to a provider network 'A' and private geneve networks.  If the mtu of private networks (1442 in normal cases) is lesser than that of provider network (1500), then there is no need for neutron ml2ovn to set options:gateway_mtu=1500 even if the config option to enable gateway mtu is set.

Comment 5 Eran Kuris 2021-11-04 14:45:29 UTC
After a debug session with Numan I am removing the blocker bug.
This issue probably was in our product but we started to see it after a new patch was added in core ovn that expose the problem.

The issue is important to be fixed because its impacts external connectivity

Comment 6 Elvira 2021-11-09 14:17:21 UTC
Hi Eran! We also think this should be fixed in OSP, but we moved that to BZ2019938 in order to leave this bug as a tracked for the initial FDP bug. Therefore I'm setting the TestOnly keyword again. Please answer back if I'm missing something!

Comment 8 Elvira 2021-11-10 14:19:41 UTC
*** Bug 2017424 has been marked as a duplicate of this bug. ***


Note You need to log in before you can comment on or make changes to this bug.