Note: This bug is displayed in read-only format because the product is no longer active in Red Hat Bugzilla.

Bug 2073652

Summary: [DDF] Undercloud network guidelines appear to contradict each other
Product: Red Hat OpenStack Reporter: Direct Docs Feedback <ddf-bot>
Component: documentationAssignee: Greg Rakauskas <gregraka>
Status: CLOSED CURRENTRELEASE QA Contact: RHOS Documentation Team <rhos-docs>
Severity: unspecified Docs Contact:
Priority: unspecified    
Version: 16.2 (Train)CC: dsneddon, gregraka, hakhande, jamsmith
Target Milestone: ---Keywords: Triaged
Target Release: ---   
Hardware: All   
OS: All   
Whiteboard:
Fixed In Version: Doc Type: If docs needed, set a value
Doc Text:
Story Points: ---
Clone Of: Environment:
Last Closed: 2022-04-14 14:12:40 UTC Type: ---
Regression: --- Mount Type: ---
Documentation: --- CRM:
Verified Versions: Category: ---
oVirt Team: --- RHEL 7.3 requirements from Atomic Host:
Cloudforms Team: --- Target Upstream Version:
Embargoed:
Bug Depends On: 1948496    
Bug Blocks:    

Comment 1 Greg Rakauskas 2022-04-11 16:30:15 UTC
Hi,

I am combining BZ 2073653 with BZ 2073652.

Related to BZ 1948496.

In the RHOSP 16.2, "Director Installation and Usage" guide, the reporter
observes that "Point#1" is confusing when reading "Point#2."

   Point #1:
   ---------
   "... it is recommended to use a 10 Gbps interface for Provisioning network 
   traffic, especially if you want to provision a large number of nodes in your
   overcloud environment."

   Point #2:
   ---------
   "Typically, the amount of traffic is relatively low on provisioning and
   control plane networks, and they do not require high bandwidth or load
   balancing."

Thanks,
--Greg

Comment 2 Greg Rakauskas 2022-04-11 16:31:36 UTC
*** Bug 2073653 has been marked as a duplicate of this bug. ***