Bug 2227742 - Collectd is unable to reconnect after QDR restart [NEEDINFO]
Summary: Collectd is unable to reconnect after QDR restart
Keywords:
Status: CLOSED DUPLICATE of bug 2229937
Alias: None
Product: Red Hat OpenStack
Classification: Red Hat
Component: collectd-sensubility
Version: 17.1 (Wallaby)
Hardware: Unspecified
OS: Unspecified
medium
medium
Target Milestone: z2
: ---
Assignee: Martin Magr
QA Contact: Leonid Natapov
Michael Geary
URL:
Whiteboard:
Depends On:
Blocks:
TreeView+ depends on / blocked
 
Reported: 2023-07-31 09:02 UTC by Leonid Natapov
Modified: 2023-08-10 15:01 UTC (History)
4 users (show)

Fixed In Version:
Doc Type: If docs needed, set a value
Doc Text:
Clone Of:
Environment:
Last Closed: 2023-08-10 11:15:35 UTC
Target Upstream Version:
Embargoed:
ifrangs: needinfo? (mmagr)


Attachments (Terms of Use)


Links
System ID Private Priority Status Summary Last Updated
Red Hat Issue Tracker OSP-27037 0 None None None 2023-07-31 09:05:31 UTC

Description Leonid Natapov 2023-07-31 09:02:49 UTC
Description of problem:
When restarting QDR collectd is unable to reconnect.

collectd logs shows the following error:

[2023-07-27 13:38:18] amqp1 plugin: PN_TRANSPORT_CLOSED: amqp:connection:framing-error: connection aborted
[2023-07-27 13:38:19] amqp1 plugin: PN_TRANSPORT_CLOSED: proton:io: Connection refused - disconnected 172.17.1.85:5666
[2023-07-27 13:38:20] amqp1 plugin: PN_TRANSPORT_CLOSED: proton:io: Connection refused - disconnected 172.17.1.85:5666

And collect-sensubility stops working.

W/A: Restart collectd

Should be solved in collectd-sensubility 0.2.1

Comment 4 Leonid Natapov 2023-08-10 11:15:35 UTC

*** This bug has been marked as a duplicate of bug 2229937 ***

Comment 5 Jenny-Anne Lynch 2023-08-10 15:01:03 UTC
Set requires_doc_text flag to minus (-). Doc text covered in bug 2229937.


Note You need to log in before you can comment on or make changes to this bug.