RHEL Engineering is moving the tracking of its product development work on RHEL 6 through RHEL 9 to Red Hat Jira (issues.redhat.com). If you're a Red Hat customer, please continue to file support cases via the Red Hat customer portal. If you're not, please head to the "RHEL project" in Red Hat Jira and file new tickets here. Individual Bugzilla bugs in the statuses "NEW", "ASSIGNED", and "POST" are being migrated throughout September 2023. Bugs of Red Hat partners with an assigned Engineering Partner Manager (EPM) are migrated in late September as per pre-agreed dates. Bugs against components "kernel", "kernel-rt", and "kpatch" are only migrated if still in "NEW" or "ASSIGNED". If you cannot log in to RH Jira, please consult article #7032570. That failing, please send an e-mail to the RH Jira admins at rh-issues@redhat.com to troubleshoot your issue as a user management inquiry. The email creates a ServiceNow ticket with Red Hat. Individual Bugzilla bugs that are migrated will be moved to status "CLOSED", resolution "MIGRATED", and set with "MigratedToJIRA" in "Keywords". The link to the successor Jira issue will be found under "Links", have a little "two-footprint" icon next to it, and direct you to the "RHEL project" in Red Hat Jira (issue links are of type "https://issues.redhat.com/browse/RHEL-XXXX", where "X" is a digit). This same link will be available in a blue banner at the top of the page informing you that that bug has been migrated.
Bug 2232637 - SELinux prevents the systemd-timesyncd process from watching the /run/systemd/ directory [rhel-9.2.0.z]
Summary: SELinux prevents the systemd-timesyncd process from watching the /run/systemd...
Keywords:
Status: CLOSED ERRATA
Alias: None
Product: Red Hat Enterprise Linux 9
Classification: Red Hat
Component: selinux-policy
Version: CentOS Stream
Hardware: x86_64
OS: Linux
medium
medium
Target Milestone: rc
: ---
Assignee: Nikola Knazekova
QA Contact: Milos Malik
URL:
Whiteboard:
Depends On: 2175137
Blocks:
TreeView+ depends on / blocked
 
Reported: 2023-08-17 17:07 UTC by RHEL Program Management Team
Modified: 2023-10-03 08:33 UTC (History)
9 users (show)

Fixed In Version: selinux-policy-38.1.11-2.el9_2.4
Doc Type: Bug Fix
Doc Text:
Cause: SELinux prevents the systemd-timesyncd process from watching the /run/systemd/ directory Consequence: This bug is preventing systemd-timedated from starting in OpenShift 4.13 installations that disable chronyd. Fix: Allow systemd-timedated watch init runtime dir Result: No SELinux denials
Clone Of: 2175137
Environment:
Last Closed: 2023-09-12 10:02:49 UTC
Type: ---
Target Upstream Version:
Embargoed:


Attachments (Terms of Use)


Links
System ID Private Priority Status Summary Last Updated
Red Hat Issue Tracker RHELPLAN-165988 0 None None None 2023-08-17 17:09:20 UTC
Red Hat Product Errata RHBA-2023:5062 0 None None None 2023-09-12 10:02:55 UTC

Comment 10 errata-xmlrpc 2023-09-12 10:02:49 UTC
Since the problem described in this bug report should be
resolved in a recent advisory, it has been closed with a
resolution of ERRATA.

For information on the advisory (selinux-policy bug fix update), and where to find the updated
files, follow the link below.

If the solution does not work for you, open a new bug report.

https://access.redhat.com/errata/RHBA-2023:5062