Bug 2315666 - [Stretch cluster] Network Fence for non-graceful node shutdown taint blocked volume mount on surviving zone
Summary: [Stretch cluster] Network Fence for non-graceful node shutdown taint blocked ...
Keywords:
Status: CLOSED ERRATA
Alias: None
Product: Red Hat OpenShift Data Foundation
Classification: Red Hat Storage
Component: rook
Version: 4.17
Hardware: Unspecified
OS: Unspecified
high
high
Target Milestone: ---
: ODF 4.17.0
Assignee: Madhu Rajanna
QA Contact: Mahesh Shetty
URL:
Whiteboard:
Depends On:
Blocks: 2281703 2317853
TreeView+ depends on / blocked
 
Reported: 2024-09-30 13:05 UTC by morstad
Modified: 2024-10-31 08:15 UTC (History)
17 users (show)

Fixed In Version: 4.17.0-121
Doc Type: Bug Fix
Doc Text:
Previously, Rook was creating NetworkFence CR with an incorrect IP address when a node was tainted as out-of-service. Fencing the wrong IP address was blocking the application pods from moving to another node when a taint was added. With this fix, auto NetworkFence has been disabled in Rook when the out-of-service taint is added on the node, and application pods are no longer blocked from moving to another node.
Clone Of:
: 2317853 (view as bug list)
Environment:
Last Closed: 2024-10-30 14:36:10 UTC
Embargoed:
mashetty: needinfo-


Attachments (Terms of Use)


Links
System ID Private Priority Status Summary Last Updated
Github red-hat-storage rook pull 752 0 None open Bug 2315666: csi: Disable fencing in Rook 2024-10-11 17:03:43 UTC
Github rook rook pull 14831 0 None Merged csi: disable fencing in Rook 2024-10-11 17:02:19 UTC
Red Hat Issue Tracker OCSBZM-9272 0 None None None 2024-10-01 19:58:08 UTC
Red Hat Product Errata RHSA-2024:8676 0 None None None 2024-10-30 14:36:23 UTC

Description morstad 2024-09-30 13:05:47 UTC
Description of problem (please be detailed as possible and provide log
snippests):

Testing disaster recover with stretch cluster for OpenShift Data Foundation as defined here : https://docs.redhat.com/en/documentation/red_hat_openshift_data_foundation/4.16/html/configuring_openshift_data_foundation_disaster_recovery_for_openshift_workloads/introduction-to-stretch-cluster-disaster-recovery_stretch-cluster

Installed a product with HA configuration and simulated disaster by shutting down ALL nodes for a Zone-2.  After shutdown applied non-graceful node shutdown taint as defined here : https://kubernetes.io/blog/2023/08/16/kubernetes-1-28-non-graceful-node-shutdown-ga/ which triggered creation of a networkfence.   The networkfence impacted recovery of application on Zone-1.

Network fence : 
---------------                                          
NAME  DRIVER                               CIDRS               FENCESTATE   ...
xxxx  openshift-storage.rbd.csi.ceph.com   ["100.64.0.9/32"]   Fenced       ...


Datastore pods on surviving zone had issues mounting PVCs (read-only file system): 

Events:
  Type     Reason       Age                  From               Message
  ----     ------       ----                 ----               -------
Warning  Failed   6m9s (x4 over 7m21s)    kubelet  Error: relabel failed /var/lib/kubelet/pods/8820f331-64bc-47d1-9140-05d963f43634/volumes/kubernetes.io~csi/pvc-f892de38-e7c8-418f-9d64-cc1e958ca209/mount: lsetxattr /var/lib/kubelet/pods/8820f331-64bc-47d1-9140-05d963f43634/volumes/kubernetes.io~csi/pvc-f892de38-e7c8-418f-9d64-cc1e958ca209/mount: read-only file system
  Warning  Failed   4m52s                   kubelet  Error: relabel failed /var/lib/kubelet/pods/8820f331-64bc-47d1-9140-05d963f43634/volumes/kubernetes.io~csi/pvc-f892de38-e7c8-418f-9d64-cc1e958ca209/mount: lsetxattr /var/lib/kubelet/pods/8820f331-64bc-47d1-9140-05d963f43634/volumes/kubernetes.io~csi/pvc-f892de38-e7c8-418f-9d64-cc1e958ca209/mount/conf: read-only file system


Deleted datastore pod on surviving zone and when recreated saw following :  

Events:
  Type     Reason       Age                  From               Message
  ----     ------       ----                 ----               -------
...
  Warning  FailedMount  21s (x9 over 2m29s)  kubelet            MountVolume.MountDevice failed for volume "pvc-5438fe65-a911-4226-9d1f-d3402af17cc9" : rpc error: code = Internal desc = error generating volume 0001-0011-openshift-storage-0000000000000001-71f3c614-f564-4814-8cbb-4a0247804fb7: rados: ret=-108, Cannot send after transport endpoint shutdown


Version of all relevant components (if applicable):
OCP 4.16.10
ODF Client : 4.17.0-98.stable
ODF Foundation : 4.170-98.stable


Does this issue impact your ability to continue to work with the product
(please explain in detail what is the user impact)? yes - unable to recover in disaster scenario


Is there any workaround available to the best of your knowledge? no


Rate from 1 - 5 the complexity of the scenario you performed that caused this
bug (1 - very simple, 5 - very complex)? 3 (due to custom product install steps)


Can this issue reproducible? likely


Can this issue reproduce from the UI? no


If this is a regression, please provide more details to justify this:


Steps to Reproduce:
1. Establish cluster in Stretch configuration
2. Install Product w/ HA configuration with datastores using RWO to access ocs-storagecluster-ceph-rbd storage
3. Simulate Zone outage for Zone-2 by shutting down all nodes
4. Add taint for non-graceful shutdown to Zone-2 nodes
    `kubectl taint nodes <node-name> node.kubernetes.io/out-of-service=nodeshutdown:NoExecute`
5. Monitor kube resources on surviving zone - all should be able to access storage


Actual results:
Pods on surviving zone, unable to mount select PVCs :  

Events:
  Type     Reason       Age                  From               Message
  ----     ------       ----                 ----               -------
...
  Warning  FailedMount  21s (x9 over 2m29s)  kubelet            MountVolume.MountDevice failed for volume "pvc-5438fe65-a911-4226-9d1f-d3402af17cc9" : rpc error: code = Internal desc = error generating volume 0001-0011-openshift-storage-0000000000000001-71f3c614-f564-4814-8cbb-4a0247804fb7: rados: ret=-108, Cannot send after transport endpoint shutdown

Expected results:
Pods on surviving zone are able to mount PVCs

Additional info:

When Zone-2 was restored and the non-graceful taint removed, the mount error was resolved.   All pods running successfully on surviving zone.

Comment 8 morstad 2024-10-01 20:08:30 UTC
Re-ran same test tainting one zone of nodes with non-graceful shutdown and NO networkfence was created.  Approx 6hrs after taint, multiple networkfences were created per node.  Unfortunately the CIDRs were incorrect (for nodes in surviving zone) taking down application.

Comment 41 errata-xmlrpc 2024-10-30 14:36:10 UTC
Since the problem described in this bug report should be
resolved in a recent advisory, it has been closed with a
resolution of ERRATA.

For information on the advisory (Important: Red Hat OpenShift Data Foundation 4.17.0 Security, Enhancement, & Bug Fix Update), and where to find the updated
files, follow the link below.

If the solution does not work for you, open a new bug report.

https://access.redhat.com/errata/RHSA-2024:8676