Bug 2532356 (CVE-2026-89472) - CVE-2026-89472 kernel: power: supply: charger-manager: register regulators before exposing sysfs
Summary: CVE-2026-89472 kernel: power: supply: charger-manager: register regulators be...
Keywords:
Status: NEW
Alias: CVE-2026-89472
Product: Security Response
Classification: Other
Component: vulnerability
Version: unspecified
Hardware: All
OS: Linux
medium
medium
Target Milestone: ---
Assignee: Product Security DevOps Team
QA Contact:
URL:
Whiteboard:
Depends On:
Blocks:
TreeView+ depends on / blocked
 
Reported: 2026-09-11 22:30 UTC by OSIDB Bzimport
Modified: 2026-09-16 05:48 UTC (History)
17 users (show)

Fixed In Version:
Clone Of:
Environment:
Last Closed:
Embargoed:


Attachments (Terms of Use)

Description OSIDB Bzimport 2026-09-11 22:30:59 UTC
In the Linux kernel, the following vulnerability has been resolved:

power: supply: charger-manager: register regulators before exposing sysfs

charger_manager_remove() and the err_reg_extcon probe error path free each
charger regulator with regulator_put() before tearing down the power_supply
sysfs entries (power_supply_unregister()). charger_manager_remove() also
calls try_charger_enable(cm, false) after the regulator_put() loop. A
concurrent write to a charger's externally_control sysfs attribute that
lands between regulator_put() and power_supply_unregister() can run
charger_externally_control_store() and call try_charger_enable(), which,
when charging is enabled, dereferences the already-freed consumer handle.
When charging is enabled, try_charger_enable(cm, false) in .remove() also
dereferences the freed handles directly. Both leave use-after-free windows.
Symmetrically, probe registers the sysfs entries (power_supply_register)
before acquiring the regulators (regulator_get, inside
charger_manager_register_extcon), so userspace can reach externally_control
before the regulators are available.

Split charger_manager_register_extcon() on the sync/async boundary:
charger_manager_get_regulators() (regulator_get only, no async producer)
now runs before power_supply_register() so sysfs is not live before
regulators are available, and charger_manager_register_extcon() keeps only
the extcon notifier/work setup, still after power_supply_register() so a
power_supply_register() failure cannot reach extcon setup. This keeps the
sysfs setup/teardown ordering symmetric without introducing an asynchronous
producer on the earlier probe-error path.

Move power_supply_unregister() and try_charger_enable(cm, false) ahead of
the regulator_put() loop on both teardown paths, and adjust err_reg_extcon
(power_supply_unregister() then fall through err_regulator for
regulator_put(); get_regulators self-rolls back on its own failure).

This does not address the separate extcon-notifier-driven deref of the same
handles, which needs its own synchronization design.

Found by an in-house static analysis tool.