Description OSIDB Bzimport 2026-09-17 19:33:51 UTC
In the Linux kernel, the following vulnerability has been resolved:

iommu/tegra241-cmdqv: Require exactly one Stream ID for a vSID

tegra241_vintf_init_vsid() maps a guest vSID to a single physical Stream ID
taken from master->streams[0], and only warns when the device does not have
exactly one stream. A device with several streams gets only its first one
mapped, so a guest vSID invalidation cannot reach the others' ATC and IOTLB
entries; a device with none makes master->streams a ZERO_SIZE_PTR, read out
of bounds.

Reject the mapping with -EOPNOTSUPP if master->num_streams is not one.


Note You need to log in before you can comment on or make changes to this bug.