Description of problem: The following error shows up: Traceback (most recent call last): File "/usr/share/system-config-printer/gtkinklevel.py", line 60, in expose_event self.draw (ctx) File "/usr/share/system-config-printer/gtkinklevel.py", line 66, in draw fill_point = self._level / 100.0 TypeError: unsupported operand type(s) for /: 'NoneType' and 'float' It happens when one tries to look at "Ink/Toner Levels" for HP LaserJet 4250 printer. A visual effect is that one gets three colums and there are "level" icons in the first two with labels underneath ("Black Cartridge ...", "Maitenance Kit ..." and only a label in the third one. That label happens to be "220V-Q5422A". Version-Release number of selected component (if applicable): system-config-printer-1.1.15-6.fc12 How reproducible: Every time in circumstances described above. Additional information: Very far from beeing a showstopper.
Please attach the /var/cache/cups/*.ipp file corresponding to the queue which caused the system-config-printer crash. *** This bug has been marked as a duplicate of bug 541882 ***
Created attachment 381625 [details] HP-LaserJet-4250.ipp from /var/cache/cups > Please attach the /var/cache/cups/*.ipp file