Bug 699816 - Wrong timeout-valiue in OracleValidConnectionChecker
Summary: Wrong timeout-valiue in OracleValidConnectionChecker
Keywords:
Status: CLOSED WONTFIX
Alias: None
Product: JBoss Enterprise Application Platform 4
Classification: JBoss
Component: jbossas
Version: 4.3.0
Hardware: Unspecified
OS: Unspecified
unspecified
high
Target Milestone: ---
: ---
Assignee: Fernando Nasser
QA Contact:
URL:
Whiteboard:
Depends On:
Blocks:
TreeView+ depends on / blocked
 
Reported: 2011-04-26 16:41 UTC by Ricardo Arguello
Modified: 2015-09-21 00:48 UTC (History)
1 user (show)

Fixed In Version:
Doc Type: Bug Fix
Doc Text:
Clone Of:
Environment:
Last Closed: 2015-09-21 00:48:35 UTC
Type: ---
Embargoed:


Attachments (Terms of Use)

Description Ricardo Arguello 2011-04-26 16:41:04 UTC
Description of problem:

OracleValidConnectionChecker calls oracle.jdbc.driver.OracleConnection.pingDatabase(5000) - 5000 is used as timeout in seconds! by pingDatabase furthermore it would be nice if the timeout would be configurable (or at least easy to override)

Version-Release number of selected component (if applicable):

JBoss EAP 4.3.0_CP09

Comment 1 Ricardo Arguello 2011-04-26 16:46:17 UTC
This is the JBoss Application Server (jboss.org) related bug, reported against JBoss AS 4.2.3, JBoss AS 5.0.1 and JBoss AS 5.1.0:

CLONE - Wrong timeout-valiue in OracleValidConnectionChecker
https://issues.jboss.org/browse/JBAS-9381

It is Fixed in JBoss EAP 5.1.0.

Please fix this in JBoss EAP 4.x, it is a major bug!