Created attachment 699931 [details] BR44 Description of problem: Data in BR44 CCP (certified cloud provider) for partial hour or less than 1Hour is not calculated correctly e.x when Time is less 1 hour 0.32 is not accurate display, can we translate 0.32 to 20min, or 1/3 or a tooltip ? In addition to PRD32 Bug 883137 - (vm_inventory_report) PRD32 - [RFE] [rhevm-reports] CCP (certified cloud provider) report Version-Release number of selected component (if applicable): 3.2/SF7 How reproducible: always Steps to Reproduce: 1.install rhevm+report+dwh 2.create some VMs 3.Open BR44 4.Examine the Report right away and verify the uptime when its less than 1H 5.wait for data to aggregate 2D and more 6.Repeat 4-5 Actual results: when its less than 1H display 0.32 Expected results: When uptime is less than 1H, data should display correctly (0.32 = 1/3H or 20min) When its more than 1H calculate correctly e.x 354.54H the .54 should be correct Additional info:
Dan, do you want me to round to hour or add a tooltip? Yaniv
(In reply to comment #1) > Dan, do you want me to round to hour or add a tooltip? > > > > > Yaniv Can't we just show hour:minute ?
(In reply to comment #2) > (In reply to comment #1) > > Dan, do you want me to round to hour or add a tooltip? > > > > > > > > > > Yaniv > > Can't we just show hour:minute ? It will cause sorting to stop working.
I see, a tooltip then. Will it show in an exported report though?
(In reply to comment #4) > I see, a tooltip then. Will it show in an exported report though? no
Fixed, 3.2/sf9 Shows correct tool tip for existence time below 1H e.x 0.16 --> 9M Fixed, 3.2/sf9
Created attachment 707738 [details] Fixed-sf9
Since the problem described in this bug report should be resolved in a recent advisory, it has been closed with a resolution of ERRATA. For information on the advisory, and where to find the updated files, follow the link below. If the solution does not work for you, open a new bug report. http://rhn.redhat.com/errata/RHEA-2013-0887.html