Description of problem: User is not aware of what host has been selected to be a proxy to fence a host. Version-Release number of selected component (if applicable): sf9 How reproducible: always Steps to Reproduce: 1. have an up and running env with 2 hosts at least with pm configured 2. restart one of the hosts Actual results: on event tab you will see a message like : Host XXXX was restarted by vdcadmin. Expected results: "Host XXXX was restarted by vdcadmin, Host YYYY was selected as a fencing proxy". Additional info: This is of course very important when there are more than 2 hosts and many clusters.
Restart is composed from stop + start. Two internal FenceBase commands (StopVDS,StartVDS) are invoked. I think that we should use the VdcReturnValue object, and put on it the host that is used as the proxy agent (which is calculated at FenceExecutor.findVdsToFence).
verified
3.2 has been released