Bug 97554 - smartctl doesn't show real temperature on IBM drives
Summary: smartctl doesn't show real temperature on IBM drives
Keywords:
Status: CLOSED NEXTRELEASE
Alias: None
Product: Red Hat Linux
Classification: Retired
Component: kernel-utils
Version: 9
Hardware: All
OS: Linux
high
medium
Target Milestone: ---
Assignee: Arjan van de Ven
QA Contact: Brian Brock
URL:
Whiteboard:
Depends On:
Blocks:
TreeView+ depends on / blocked
 
Reported: 2003-06-17 18:05 UTC by Ronny Buchmann
Modified: 2007-03-27 04:07 UTC (History)
2 users (show)

Fixed In Version:
Doc Type: Bug Fix
Doc Text:
Clone Of:
Environment:
Last Closed: 2003-07-27 21:00:04 UTC
Embargoed:


Attachments (Terms of Use)

Description Ronny Buchmann 2003-06-17 18:05:53 UTC
Description of problem:
The temperature value on IBM drives is stored in an encodeded form. The provided
version of smartctl doesn't know how to decode it.

Version-Release number of selected component (if applicable):
2.1

How reproducible:
always with IBM drives

Steps to Reproduce:
1. smartctl -a /dev/hd?
2.
3.
    
Solution:
upgrade smartctl/smartd to the ones from http://smartmontools.sf.net

Comment 1 Ronny Buchmann 2003-07-27 21:00:04 UTC
Fixed in severn, so I think I can close this bug.