Description of problem: When using CFME in combination with RHEV, the "Used" storage per VM is not shown correctly. Although CFME detects that the VM is using Thin Provisioning, the "Used" storage always matches the "Allocated" storage. Version-Release number of selected component (if applicable): 5.5.2 How reproducible: tested with RHEV 3.4 and RHEV 3.5 Steps to Reproduce: 1. add a RHEV provider 2. make sure there is a least one VM with "thin provisioning" 3. navigate to the VM details and check the "Datastore Allocation Summary" and "Datastore Actual Usage Summary" section Actual results: "Used" always matches "Allocated" Expected results: "Used" should match the Actual usage shown in the RHEV UI. Additional info: Only tested with NFS storage!
Created attachment 1142133 [details] screenshot showing usage data in CFME UI
Created attachment 1142134 [details] screenshot showing using in RHEV UI
This bug was actually fixed by the patch for bug 1309275 Moving to ON_QA to be verified.
*** This bug has been marked as a duplicate of bug 1309275 ***