Created attachment 1277337 [details] screenshot Description of problem: Version-Release number of selected component (if applicable): Version 5.8.0.13-rc2.20170502165848_0f98658 How reproducible: 100% Steps to Reproduce: 1.Navigate to Compute->Infrastructure->PXE 2.Go to Customization Templates accordion 3.From Configuration button Add a New Customization Template 4.Add another Customization Template with the same name Actual results: Expected results: The UI should display the "Name has already been taken" flash error message. Additional info:
This change validates the name uniqueness within each pxe_image_type. PR https://github.com/ManageIQ/manageiq/pull/15495
*** Bug 1450927 has been marked as a duplicate of this bug. ***
Verified in Version 5.9.0.2.20171010190026_0413a06
Added cfme-5.8.z flag
5.7.4.1 also needs this fix