Description of problem: Doing a update from 17.0 to 17.1 fails as there is a cut in control plane. The reason is that pacemaker container naming convention changed from 17.0 to 17.1 causing the services behind the pacemaker cluster to not be available during the controller update run. In order to have that cut, we implemented: - a test that make the update fail and present the user with the required command to trigger; - a new external run command that adjust the pacemaker container's name to their 17.1 value before the update of the controllers
*** Bug 2176191 has been marked as a duplicate of this bug. ***
Since the problem described in this bug report should be resolved in a recent advisory, it has been closed with a resolution of ERRATA. For information on the advisory (Release of components for Red Hat OpenStack Platform 17.1 (Wallaby)), and where to find the updated files, follow the link below. If the solution does not work for you, open a new bug report. https://access.redhat.com/errata/RHEA-2023:4577