Bug 28904 - Install only installs array device C0
Install only installs array device C0
Status: CLOSED RAWHIDE
Product: Red Hat Linux
Classification: Retired
Component: dev (Show other bugs)
7.1
i386 Linux
high Severity high
: ---
: ---
Assigned To: Matt Wilson
Brock Organ
:
Depends On:
Blocks:
  Show dependency treegraph
 
Reported: 2001-02-22 14:28 EST by Bryan Leopard
Modified: 2005-10-31 17:00 EST (History)
2 users (show)

See Also:
Fixed In Version:
Doc Type: Bug Fix
Doc Text:
Story Points: ---
Clone Of:
Environment:
Last Closed: 2001-03-29 18:18:53 EST
Type: ---
Regression: ---
Mount Type: ---
Documentation: ---
CRM:
Verified Versions:
Category: ---
oVirt Team: ---
RHEL 7.3 requirements from Atomic Host:
Cloudforms Team: ---


Attachments (Terms of Use)

  None (edit)
Description Bryan Leopard 2001-02-22 14:28:53 EST
Unable to see the drives connected to a second array controller in the 
system due to the fact that the only array device installed is C0.  This 
will happen with any two array controllers in the system.
Comment 1 Michael Fulbright 2001-02-23 11:42:25 EST
What type of hardware is this?
Comment 2 Bryan Leopard 2001-02-23 11:55:01 EST
This will happen on any Compaq ProLiant server.  It has to do with the fact 
that the OS installer does not install any more device nodes than C0, so the 
second controller does not have a device node associated with it.
Comment 3 Preston Brown 2001-02-23 15:58:43 EST
makedev bug?
Comment 4 Glen Foster 2001-02-23 16:49:30 EST
This defect is considered MUST-FIX for Florence Release-Candidate #2
Comment 5 Matt Wilson 2001-02-28 10:17:12 EST

*** This bug has been marked as a duplicate of 26649 ***
Comment 6 Matt Wilson 2001-03-29 18:18:48 EST
(reopening this, it was a dev package bug, different than the anaconda bug)
Comment 7 Matt Wilson 2001-03-29 18:19:49 EST
fixed in dev-3.1.0-14