Description of problem: Dell iDRAC 6 does not work unless the parameter "-c" is passed to fence_drac5, which is read from cluster.conf as 'cmd_prompt="your_prompt"'. Version-Release number of selected component (if applicable): cman-2.0.98-1.el5 How reproducible: Everytime Steps to Reproduce: 1. Setup a cluster with Conga 2. Configure fencing for a system with a Dell iDRAC 6 3. Fencing fails Actual results: If the user chooses "Dell DRAC", there is no field for "command prompt". If they manually change the fence_agent to "fence_drac5" and add "cmd_prompt" (gathered from the actual iDRAC 6), fencing will work. This only applies to the iDRAC 6, the iDRAC on the Dell blades needs support too (see bug 496748). Expected results: A field should be added for "command prompt" or a new entry created for iDRAC. Additional info: See bug 496713 for SSH support on the iDRAC in Conga See bug 496748 for SM-CLP cli support for the iDRAC
*** Bug 572514 has been marked as a duplicate of this bug. ***
*** Bug 572978 has been marked as a duplicate of this bug. ***