Bugzilla will be upgraded to version 5.0. The upgrade date is tentatively scheduled for 2 December 2018, pending final testing and feedback.
Bug 646764 - RHEL5.6 Include DL580 G7 in bfsort whitelist [rhel-5.4.z]
RHEL5.6 Include DL580 G7 in bfsort whitelist [rhel-5.4.z]
Status: CLOSED ERRATA
Product: Red Hat Enterprise Linux 5
Classification: Red Hat
Component: kernel (Show other bugs)
5.6
All Linux
high Severity high
: rc
: ---
Assigned To: Jiri Pirko
Red Hat Kernel QE team
: ZStream
Depends On: 644879
Blocks:
  Show dependency treegraph
 
Reported: 2010-10-26 03:28 EDT by RHEL Product and Program Management
Modified: 2015-05-04 21:21 EDT (History)
13 users (show)

See Also:
Fixed In Version: kernel-2.6.18-164.30.1.el5
Doc Type: Bug Fix
Doc Text:
Story Points: ---
Clone Of:
Environment:
Last Closed: 2010-11-23 10:19:51 EST
Type: ---
Regression: ---
Mount Type: ---
Documentation: ---
CRM:
Verified Versions:
Category: ---
oVirt Team: ---
RHEL 7.3 requirements from Atomic Host:
Cloudforms Team: ---


Attachments (Terms of Use)


External Trackers
Tracker ID Priority Status Summary Last Updated
Red Hat Product Errata RHSA-2010:0907 normal SHIPPED_LIVE Important: kernel security and bug fix update 2010-11-23 10:19:19 EST

  None (edit)
Description RHEL Product and Program Management 2010-10-26 03:28:15 EDT
This bug has been copied from bug #644879 and has been proposed
to be backported to 5.4 z-stream (EUS).
Comment 2 Jiri Pirko 2010-11-04 18:33:50 EDT
in kernel-2.6.18-164.30.1.el5

linux-2.6-pci-include-dl580-g7-in-bfsort-whitelist.patch
Comment 6 Tony Camuso 2010-11-10 07:59:06 EST
HP has verified that the 2.6.18-230.el5.x86_64.rpm kernel correctly applies bfsort to DL580 G7.
Comment 9 Matt Wilson 2010-11-16 01:31:39 EST
Some DL580 G7 systems have the following in DMI:

System Information
        Manufacturer: Hewlett-Packard
        Product Name: ProLiant DL580 G7

The patch needs to be re-worked with another entry;

	{
		.callback = set_bf_sort,
		.ident = "Hewlett-Packard ProLiant DL580 G7",
		.matches = {
			DMI_MATCH(DMI_SYS_VENDOR, "Hewlett-Packard"),
			DMI_MATCH(DMI_PRODUCT_NAME, "ProLiant DL580 G7"),
		},
	},
Comment 10 Tony Camuso 2010-11-16 08:03:19 EST
Matt, 

I don't think that's necessary, since the DL580 G7 is a very recently announced product with a critical BIOS update scheduled for release this Friday, Nov 19, that includes the correct DMI vendor id string. 

DL580 G7 customers who have had problems with device enumeration have been advised to upgrade the BIOS.
Comment 13 errata-xmlrpc 2010-11-23 10:19:51 EST
An advisory has been issued which should help the problem
described in this bug report. This report is therefore being
closed with a resolution of ERRATA. For more information
on therefore solution and/or where to find the updated files,
please follow the link below. You may reopen this bug report
if the solution does not work for you.

http://rhn.redhat.com/errata/RHSA-2010-0907.html

Note You need to log in before you can comment on or make changes to this bug.