Hide Forgot
Description of problem: trying to put power_wait option in my cluster.conf Version-Release number of selected component (if applicable): cman-3.0.12-23.el6_0.4.x86_64 How reproducible: always Steps to Reproduce: 1. this line <fencedevice agent="fence_ilo" ipaddr="10.4.192.212" login="fenceuser" name="ilonode01" passwd_script="/usr/local/bin/pwd_ilonode01.sh"/> [root@rhev1 cluster]# ccs_config_validate Configuration validates 2. change into <fencedevice agent="fence_ilo" ipaddr="10.4.192.212" login="fenceuser" name="ilonode01" passwd_script="/usr/local/bin/pwd_ilonode01.sh" power_wait="5"/> 3. run [root@rhev1 cluster]# ccs_config_validate Actual results: Relax-NG validity error : Extra element fencedevices in interleave tempfile:20: element fencedevices: Relax-NG validity error : Element cluster failed to validate content tempfile:15: element device: validity error : IDREF attribute name references an unknown ID "ilonode02" Configuration fails to validate Expected results: Configuration validates Additional info: It seems power_wait should be ok in /usr/sbin/fence_ilo..... I have fence-agents-3.0.12-8.el6_0.2.x86_64 and there is inside it: def main(): device_opt = [ "help", "version", "agent", "quiet", "verbose", "debug", "action", "ipaddr", "login", "passwd", "passwd_script", "ssl", "ribcl", "inet4_only", "inet6_only", "ipport", "power_timeout", "shell_timeout", "login_timeout", "power_wait" ]
This issue has already been addressed. Thanks for your report. *** This bug has been marked as a duplicate of bug 618705 ***